Arteriosclerosis Detector DAS-1000

Arteriosclerosis Detector DAS-1000
Details:
Arteriosclerosis detector DAS-1000 product specifications Input power: 200VA Monitor: 19" LCD screen, resolution 1440x900 Applicable arm circumference: 20-~30cm Input and output ports: 2 USB interfaces Printing report paper: special report paper, ordinary A4 report paper ※Product specifications and functions are subject to upgrade or change without prior notice.
Send Inquiry
Description
Send Inquiry

 

Arteriosclerosis detector

DAS-1000

product specifications

Input power: 200VA

Monitor: 19" LCD screen, resolution 1440x900

Applicable arm circumference: 20-~30cm

Input and output ports: 2 USB interfaces

Printing report paper: special report paper, ordinary A4 report paper

※Product specifications and functions are subject to upgrade or change without prior notice.

 

Product advantages

Easy to understand: A4 color printed measurement report fully presents various measurement data and gives normal standard values ​​as a reference.

Quick operation: rapid measurement, can detect 4 arterial pulse waves at the same time (left upper arm artery, right upper arm artery, left ankle artery, right ankle artery)

Diverse expansion: A complete database system that enables data storage, historical data tracking of patient case data, and data backup, and can be connected to health management software systems.

System maintenance function: Users can perform air tightness testing on their own.

Humanized design: 270-degree rotating color LCD display for convenient measurement operations.

Use a special cuff for pulse sensor to accurately measure, adopt PWV method, oscillometric method, and parameter analysis method

Fully automatic synchronous or asynchronous measurement of limbs, PWV, ABI, ASI and other arteriosclerosis parameters comprehensively reflect the degree of arteriosclerosis.

Humanized user interface instructions.

Easy to operate, non-invasive detection, improve operating efficiency.

 

Functional performance

Use a special cuff for pulse sensor for accurate measurement, and adopt PWV method, oscillometric method and parameter analysis method.

Fully automatic synchronous or asynchronous measurement of limbs, PWV, ABI, ASI and other arteriosclerosis parameters comprehensively reflect the degree of arteriosclerosis

Humanized user interface instructions

Easy to operate, non-invasive detection, improve operating efficiency

 

Hot Tags: arteriosclerosis detector das-1000, China, manufacturers, factory, cheap, famous, with CE, no.1, leading company, medical equipments, health product

Product parameters

Input power: 200VA

Monitor: 19" LCD screen, resolution 1440x900

Applicable arm circumference: 20-~30cm

Input and output port: USB interface

Printing report paper: special report paper, ordinary A4 report paper

Detection parameters:

Limb systolic blood pressure (SBP)

Diastolic blood pressure of limbs (DBP)

Mean limb pressure (MAP)

Pulse pressure of limbs (PP)

SV (stroke volume)

Co (output per distraction)

SVR (peripheral resistance)

ET (left ventricular systolic time)

HR(heart rate)

BMI (body mass index)

PWV (pulse wave velocity)

ABI (ankle-brachial index)

ASI (arteriosclerosis index)

C1 (aortic compliance index)

C2 (large artery compliance index)

Send Inquiry